Guide
LED lights explained: lumens, colour temperature and IP rating
Three numbers on an LED datasheet decide whether a light suits your space. Here is what each one means and how to put it in an RFQ.
An LED RFQ that says only “LED flood light, 100 W” will return quotes for very different products. Brightness, colour and protection against dust and water are three separate numbers, and buyers who name all three get comparable quotations. This guide explains them in plain terms.
Lumens: how much light
Lumens measure the visible light a lamp produces, so they indicate brightness. Watts tell you how much power the lamp uses. With older bulbs watts were a rough guide to brightness, but with LED the two are far apart, so request lumens. A rule of thumb from lighting guides is that the larger the area, the more lumens you need, and small focused tasks need fewer.
Two related terms help you compare lights.
- Efficacy: lumens produced per watt consumed. A higher figure means more light for the same power.
- Beam angle: how widely the light spreads. A narrow beam throws light a long way, and a wide beam covers an area.
Colour temperature: how the light looks
Colour temperature is given in kelvin (K) and describes tone, not brightness.
- 2700K to 3000K: warm, yellowish light, close to a traditional bulb.
- 4000K: neutral white.
- 5000K to 6500K: cool, bluish light similar to daylight.
Warm tones feel softer and suit hospitality and living spaces. Neutral to cool light is often chosen for detailed work such as inspection or painting. If a project has a lighting design, copy the kelvin value from it. Mixing tones in one room is a common reason for rejected deliveries, so state one value per fixture type.
IP rating: dust and water
An IP rating has two digits. The first (0 to 6) is protection against solid objects and dust, with 6 meaning dust-tight. The second (0 to 9) is protection against water, higher meaning more protection.
- IP44: protected against splashing water from any direction, for splash-prone or sheltered locations.
- IP54: partial dust protection and splashing water.
- IP65: dust-tight and protected against low-pressure water jets.
- IP66: dust-tight and protected against powerful water jets.
- IP67: dust-tight and protected against immersion up to one metre for up to 30 minutes.
For IP68 the test depth and time are set by the manufacturer, so ask for the datasheet. Outdoor lighting and washdown areas usually call for a higher second digit than indoor offices.
Drivers and dimming
Many LED fixtures need a driver, the power supply that converts mains to the voltage and current the LEDs need. Give the driver details when the luminaire is sold without one, and say whether you need dimming, for example 1 to 10 V. The catalogue lists LED drivers and switching power supplies under their own category.
Fixture types buyers ask for
- High bay luminaires for tall ceilings in warehouses and workshops. Catalogue lists a 200 W LED high-bay luminaire.
- Outdoor and street lighting, floodlights and garden lights. A solar all-in-one street light of 80 W is listed.
- Bulbs, tubes, panel lights and downlights for offices and retail.
A worked comparison
A buyer compares two flood lights, both sold as 100 W. Light A gives 10,000 lumens and light B gives 13,000 lumens at the same power, so B has a higher efficacy, 130 lumens per watt against 100. If A is 4000K and B is 6500K, the tone differs as well, and B will look bluer. The comparison is made up to show the method. Always ask for lumens and kelvin, then compare efficacy as lumens divided by watts.
Common mistakes in LED orders
- Comparing LED lights by wattage. Lumens measure the light.
- Mixing colour temperatures in one space.
- Choosing IP20 fittings for a wash-down area.
- Ignoring beam angle, which decides whether a light reaches the floor from a high ceiling.
- Treating the driver as an afterthought. A mismatched driver causes flicker or short life.
Questions to ask any supplier
- How many lumens does the fixture produce, per the datasheet?
- What is the colour temperature and the beam angle?
- What is the IP rating?
- Is the driver included, and does it dim?
- Which documents come with the goods?
What to put in the RFQ
- Fixture type and the fitting, such as E27, GU10 or integrated
- Lumens, or a target lux and the area to be lit
- Colour temperature in kelvin
- IP rating needed for the location
- Driver details and dimming type
- Mounting height, voltage and any lighting design reference
- Quantity, delivery site and date
Use the LED lights page to start a request. For a project with a lighting design, send the drawing or schedule with the RFQ.
What this guide does not do
It does not say that any luminaire we quote reaches a lumen, kelvin or IP figure. Ask for the datasheet of the exact model offered.
Ready to quote?
Send the item, specification, quantity and delivery location. Open the quote form with this topic filled in, or email sales@vmv-solutions.com.
Frequently asked questions
Are watts the same as lumens?
No. Watts measure power used and lumens measure visible light produced. Ask for lumens when you compare LED lights.
What colour temperature should I choose?
Warm light of about 2700K to 3000K looks yellowish, around 4000K is neutral white and 5000K to 6500K is cool and daylight-like. Choose by the look and task of the space.
What does IP65 mean?
The first digit 6 means dust-tight and the second digit 5 means protected against low-pressure water jets from any direction.
Do I need to name the driver?
For a luminaire without a built-in driver, yes. State the driver output and whether it must be dimmable, for example 1 to 10 V.
Do you show LED prices?
No. Each luminaire or lamp is quoted from the specification and quantity you send.
Sources
Rapid: lumens, IP ratings and Kelvin | RS: IP ratings explained