Products
MCCB and Circuit Breakers in Dubai: MCB, RCCB and Isolators
VMV Solutions LLC quotes MCCB and circuit breakers for buyers in Dubai and the UAE, together with MCBs, residual current breakers, isolators and contactors.
Circuit breakers are quoted by rating, poles and breaking capacity. VMV Solutions LLC lists breakers, isolators and switchgear accessories in its circuit protection and switching category and quotes requests from contractors, panel builders and facilities teams in Dubai. A breaker choice is a design decision, so the quotation follows the specification your engineer provides.
What is in the range
The category lists:
- Miniature circuit breakers: 1P 6 A and 2P 16 A (C curve) entries
- Moulded case circuit breaker: 63 A, 3-pole, thermo-magnetic trip unit
- Residual current breaker: 4-pole, 40 A, 100 mA
- Isolators and switch disconnectors, including a 4-pole 40 A isolator and an enclosed switch
- Contactors, auxiliary contacts, door limit switches, selector handles and shafts
- General MCB and contactor entries that invite you to state brand and rating
See the circuit protection and switching range.
MCCB, MCB and isolators in one request
An MCB protects final circuits, an MCCB protects larger circuits and sub-mains, an isolator disconnects without protecting and a residual current breaker responds to earth leakage. The MCB, MCCB and ACB guide compares them using a trade-body guide, which helps when an RFQ uses the words loosely.
ABB circuit breaker and other brand requests
Buyers who write ABB circuit breaker or name another maker in an RFQ should give the full model reference, since model families contain many variants. The catalogue mentions brand names only to identify listed items. If your project allows an equivalent, say what it must match, and ask for the datasheet.
Panel builders and contractors
- Panel builders: send the schedule with ratings, poles, breaking capacity and accessories per way
- Electrical contractors: group by distribution board
- Facilities teams: list replacement units by tag or location, with the existing model if known
Mistakes that slow a breaker order
- Writing “63 A breaker” with no poles, curve or breaking capacity.
- Mixing MCB, MCCB and isolator in one line.
- Naming a brand with no model.
- Forgetting accessories such as auxiliary contacts or handles.
- Choosing a breaker for a panel without the fault level. Breaking capacity comes from the design, not from a catalogue page.
A sample request
“Quote 3 MCCB, 3-pole, 63 A, 25 kA, thermo-magnetic trip; 40 MCB, 1-pole, C curve, 16 A, 6 kA; 6 RCCB, 4-pole, 40 A, 100 mA; 2 auxiliary contacts per MCCB; datasheets; delivery to a panel workshop in Sharjah by the 18th. Brand: as named on our schedule, or equivalent with the same ratings.” The reply can then confirm each line.
How to specify
- Breaker family: MCB, MCCB, RCCB, isolator or contactor
- Rated current and number of poles
- Breaking capacity in kA and the standard you work to
- Trip curve or trip unit type
- Accessories: auxiliary contacts, shunt trips, handles
- Brand preference or “equivalent”
- Quantity per rating, delivery site and date
How the quotation works
Send the schedule through the form, with an attachment if you have a BOQ, or call +971 50 496 8972. We confirm ratings and quantities and reply with a quotation. Prices are not shown online, and delivery timing is stated in the reply. Selection for your installation stays with your engineer.
Related items
Breakers go with cable management, LED lighting and other electrical supplies. Add them to the same list.
Ready to quote?
Send the item, specification, quantity and delivery location. Open the quote form with this topic filled in, or email sales@vmv-solutions.com.
Frequently asked questions
Do you quote ABB and Schneider breakers?
The catalogue names ABB and Schneider Electric products so you can identify them, for example an ABB 4-pole 40 A isolator and a Schneider 63 A 3-pole MCCB. Name the brand and model in your request, or write equivalent.
Which breaker items are listed?
MCBs from 1P 6 A and 2P 16 A, a 63 A 3-pole MCCB, a 4-pole 40 A residual current breaker, a 4-pole 40 A isolator, switch disconnectors, enclosed switches, contactors and auxiliary contacts.
Can you quote a breaker that is not listed?
Send the rating, poles, breaking capacity and brand. The reply states what can be supplied.
Do I need to give breaking capacity?
Yes. It tells the supplier the fault level the breaker must handle. Take it from your engineer's design.
Do you show prices?
No. Each request is quoted from the rating, poles, brand preference and quantity.
